Gas based heating · Auckland

Radiator central heating on a gas boiler

Radiator central heating

Radiators are the answer where there is an existing homes or a timber mid floor. On a condensing gas boiler they are quick to respond

How it works

Gas boiler to radiators, room by room

Flow · warm water out Return · cooled water back Gas supply
Timber floor — both mains run in the subfloor, nothing comes up Living Bedroom 1 Bedroom 2 Study Gas in Condensate to drain CONDENSING BOILER
01 — Gas boiler
Vaillant ecoTEC plus, wall hung
02 — Radiators
A valve per room, silent and fanless
03 — Flow & return
Both mains in the subfloor, up to each panel

Swipe the diagram sideways to follow the full circuit →

Quick warm-up

A boiler makes 60–70 °C water on demand, so panels can be smaller than on a heat pump and the house comes up quickly from cold.

For homes without a new slab

Timber floor, existing house, floors staying put. Flow and return run through the subfloor and come up through the boards at each radiator.

A valve per radiator

A thermostatic head on each panel sets that room and no other. Bedrooms cooler, living room warmer, spare room off — no programming.

Keep the return cool

A condensing boiler only condenses when the water coming back is below about 55 °C, so we design and balance for a wide flow-return spread rather than the hottest setting.

Questions

Gas radiator questions

Can I mix radiators and underfloor on one boiler?

Yes, and it is very common — underfloor in the slab downstairs, radiators upstairs. They run at different temperatures, so the underfloor circuit gets its own mixing valve.

Will my existing radiators work with a new condensing boiler?

They will work, but if they were sized for 80 °C water the boiler will have to run hot to satisfy them, and you lose the condensing efficiency. Sometimes the answer is to upsize a few key radiators rather than all of them. We will tell you which.

How noisy is it?

A hydronic radiator system makes no noise in the room at all — there is no fan. The only sound is the boiler itself, which on the Vaillant is 42–47 dB(A) depending on model.

What about towel rails?

They run off the same circuit and we fit them as standard in bathrooms. They can be valved so they run in summer for drying without the rest of the heating on.

Free, no obligation

Request a quote

Send the plans, or tell us what is there now. We will price the gas option and the heat pump option side by side.